Service Instruction No. 1308 E
Pressurized Magneto Pressure Test
Publications
February 2, 2007
MODELS AFFECTED
Lycoming TIO-540-A2B, -A2C; (L)TIO-540-F, -J, -V, -R, -U, -W, -AE, -AF, -AG, -AH, -AJ, -AK; TIGO-541; IO-720-B1B and IO-720-B1BD series engines.
TIME OF COMPLIANCE
At intervals not to exceed 100 hours and anytime magneto is removed or replaced.
The Model 11-10090 Air Flow Tester is available for testing the pressurization system of the Bendix 1200, D3000, D3200 and Unison Slick 6200 and 6300 series magnetos used on applicable Lycoming engines.